Contents [show]
Check the following connection for tension force NEd=600KN. S275, bolts M20/5.6. Shear at full section.
Solution
d0=22mm
p1= 65mm>2.2d0
e1=55mm>1.2d0
p2=70mm>2.4d0
e2=50mm>1.2d0
Check the shear connection for the IPE450-S275 for the design shear VEd=300KN. Bolts M20-8.8, plate...
Check the shear connection for the IPE450-S275 for the design shear VEd=500KN. Bolts M20-8.8, plate...
Check the shear connection for the IPE450-S275 for the design shear VEd=200KN. Bolts M20-8.8, plate...