Contents [show]
Calculate the maximum allowable shear force Vmax for the girder. The welded steel girder is having the cross section shown in the figure. It is fabricated of two 300 mm x30 mm flange plates and a 300 mm x 30 mm web plate. The plates are joined by four fillet welds that run continuously at the length of the girder. Each weld has an allowable load in shear of 1000 kN/m.
Solution
Calculate the maximum allowable shear force Vmax for the girder. The welded steel girder is having...
Determine the shear force and moment acting at a section passing through point C on the beam....
Calculate the member diagrams for the point load P for the pinned beam at two ends. Solut...
Calculate the member diagrams for the uniform loading q for the pinned beam at two ends. So...
Determine the minimum diameter of the rod. The axial tensile force is P=10KN. The allowable stresse...
A new bridge construction method, which was introduced by structural engineers at the Vienna Univer...